PIPELINE /MODE
IMAGER\PIPELINE [Arg1 [Arg2]] /MODE All|Continuum|Split|Survey
Specifdy in which mode the Pipeline will run. 4 modes are possible
CONTINUUM
Only produce continuum images, no data cube. In this mode, the emission is
assumed to be purely continuum, with no significant line contamination.
SURVEY
Only produce line+continuum data cubes. No attempt to separate line emis-
sion from continuum emission is made. The complete spectral coverage is im-
aged, at the velocity resolution specified by the user. This mode is espe-
cially adapted for extra-galactic work, or sources with lines close to the
spectral confusion limit.
A "continuum" image is also produced, but a more elaborate evaluation us-
ing MAP_CONTINUUM on the full data cubes is recommended after imaging.
ALL
Produce data cubes that contains line and continuum emission together.
Spectral line identification will be performed if a Catalog is present, with
the user-specified velocity range and spectral resolution around each spec-
tral line in the band.
If no Catalog is present, the complete spectral coverage is imaged, at the
velocity resolution specified by the user (this case is equivalent to the
SURVEY mode).
SPLIT
Similar to ALL, but produce data cubes that contains line and continuum
emission separately. The separation is based on filtering performed by
UV_PREVIEW.