PIPELINE /MODE

            IMAGER\PIPELINE [Arg1 [Arg2]] /MODE All|Continuum|Split|Survey

    Specifdy in which mode the Pipeline will run. 4 modes are possible

          CONTINUUM
      Only produce continuum images, no data cube. In this mode, the emission is
    assumed to be purely continuum, with no significant line contamination.

          SURVEY
      Only  produce line+continuum data cubes. No attempt to separate line emis-
    sion from continuum emission is made. The complete spectral coverage is  im-
    aged,  at  the velocity resolution specified by the user. This mode is espe-
    cially adapted for extra-galactic work, or sources with lines close  to  the
    spectral confusion limit.

      A  "continuum" image is also produced, but a more elaborate evaluation us-
    ing MAP_CONTINUUM on the full data cubes is recommended after imaging.

          ALL
      Produce data cubes that contains line  and  continuum  emission  together.
    Spectral line identification will be performed if a Catalog is present, with
    the  user-specified velocity range and spectral resolution around each spec-
    tral line in the band.

    If no Catalog is present, the complete spectral coverage is imaged,  at  the
    velocity  resolution  specified  by the user (this case is equivalent to the
    SURVEY mode).

          SPLIT
      Similar to ALL, but produce data cubes that contains  line  and  continuum
    emission  separately.  The  separation  is  based  on filtering performed by
    UV_PREVIEW.