UV_MAP /CONTINUUM

        [CLEAN\]UV_MAP [CenterX CenterY Unit] [ANGLE AngleValue]  /CONT  [Naver]
    [/INDEX Alpha] [/RANGE Min Max Type]

    Produce  a  Continuum  image  (from  all channels, or those selected  by the
    specified Velocity, Frequency or Channel range (depending on  Type)  between
    Min  Max when the option /RANGE is present), using a Multi-Frequency Synthe-
    sis, where (u,v) coordinates are scaled with Frequencies to produce an opti-
    mal beam.

      Naver is the number of initial channels that will share the same (u,v) co-
    ordinates. If not present, it is computed from  MAP_FIELD  and  MAP_CELL  to
    limit bandwidth smearing.

    In  essence,  UV_MAP  /CONTiNUUM  behaves as the combination of UV_CONTINUUM
    followed by UV_MAP, but the pseudo-continuum UV Table created by  UV_CONTIN-
    UUM is not kept by UV_MAP /CONTINUUM.

    A spectral index can be specified using option /INDEX.